Mostrar el registro sencillo del ítem
Time-dependent effect of refrigeration on viscosity and conversion kinetics of dental adhesive resins
| dc.contributor.author | Faria e Silva, André Luis | |
| dc.contributor.author | Piva, Evandro | |
| dc.contributor.author | Moraes, Rafael Ratto de | |
| dc.date.accessioned | 2013-11-18T13:58:56Z | |
| dc.date.available | 2013-11-18T13:58:56Z | |
| dc.date.issued | 2010 | |
| dc.identifier.citation | Faria-e-Silva, A.L. ; MORAES, Rafael Ratto de ; Piva, Evandro . Time-Dependent Effect of Refrigeration on Viscosity and Conversion Kinetics of Dental Adhesive Resins. European Journal of Dentistry, v. 4, p. 150-155, 2010. | pt_BR |
| dc.identifier.issn | 1305-7456 | |
| dc.identifier.uri | https://guaiaca.ufpel.edu.br/handle/123456789/784 | |
| dc.description.abstract | Objectives: This study evaluated the effect of refrigeration at 4oC and post-refrigeration times (immediate, 5, 10, 15, or 20 min) on the viscosity and conversion kinetics of adhesive bonding resins. Methods: Scotchbond Dual-Cure (3M ESPE) and Clearfil SE Bond (Kuraray) were tested. Control samples were kept at 25oC for 24 h. At each post-refrigeration time, the temperature was checked with a K-type thermocouple. Viscosity measurements as a function of temperature were performed using a cone-plate viscometer. Real-time polymerization was monitored by infrared spectroscopy. Degree of conversion (DC) was calculated for each second during polymerization, and the rate of polymerization analyzed. Data were separately submitted to two-way ANOVA and Tukey’s test (P<.05). Results: Clearfil presented faster increase in temperature after exposure to room temperature than Scotchbond. A continuous decrease in viscosity (Pa.s) was observed for both Scotchbond (0.49, 0.34, 0.30, 0.26, 0.23, 0.23) and Clearfil (0.38, 0.37, 0.34, 0.25, 0.24, 0.22). For Scotchbond, higher final DC was detected for the control (62.7%) compared with the immediate (53.3%) and 5 min (54.7%) groups. For Clearfil, the control sample (81.4%) showed higher DC than all refrigerated groups (68.8– 69.5%). Clearfil always showed significantly higher DC than Scotchbond. Conclusions: Refrigeration presented a significant time- and material-dependent effect on the viscosity and polymerization kinetics of the bonding resins. Under clinical conditions, adhesive agents should be removed from the refrigerator at least 20 min before being used. (Eur J Dent 2010;4:150-155) | pt_BR |
| dc.language.iso | en_US | pt_BR |
| dc.publisher | Medknow Publications | pt_BR |
| dc.relation.ispartofseries | v.4; | |
| dc.rights | OpenAccess | |
| dc.subject | Bonding resins | pt_BR |
| dc.subject | Degree of conversion | pt_BR |
| dc.subject | Polymerization kinetics | pt_BR |
| dc.subject | Refrigeration | pt_BR |
| dc.subject | Viscosity | pt_BR |
| dc.title | Time-dependent effect of refrigeration on viscosity and conversion kinetics of dental adhesive resins | pt_BR |
| dc.type | article | pt_BR |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Departamento de Odontologia Restauradora: Artigos avaliados por pares [80]
Abrange os arquivos de periódicos da área do Departamento de Odontologia Restauradora

